Medicontur
Bi-Flex ELON Toric
ELONgated Depth of Focus
The ELON lens with extended depth of focus provides high-quality vision empowered by Wavefront Linking technology.
Available in preloaded version through the POB-MA fully preloaded unique injection system.
Wavefront Linking Technology
EDoF Toric IOL
Preloaded injector
Medicontur Bi-Flex ELON Toric
To create minimal optical disturbances, Medicontur developed Wavefront Linking, a non-diffractive technology for a wide range of vision. This proprietary technology is based on a series of central concentric refractive zones varying in curvature and linked by specially designed linking zones.
Wavefront Linking distributes light energy continuously along the optical axis. Connected focal points result in a singular ELONgated focus, useful across the entire range of vision. With no diffractive rings, Wavefront Linking technology lowers the risk of visual disturbances compared to diffractive EDoF solutions on the market.
Central concentric refractive zones varying in curvature linked by specially designed linking zones. Continuous light energy is distributed along the optical axis with connected focal points, delivering singular elongated focus across the entire range of vision.
The ELON lens is equipped with the proprietary Bi-Flex design for long-term stability and centration. The large contact angle between the lens haptics and the capsular bag wall ensures long-term stability and visual comfort.
SEMTE hydrophobic copolymer material, ensuring high uveal biocompatibility and low levels of glistening.
The Medicontur Bi-Flex ELON lens provides excellent contrast sensitivity along the whole defocus range.
Patients can lead an active lifestyle independent of spectacles. ELON delivers high-quality vision for far and intermediate distances. Glasses may be required for near vision.
Preliminary clinical experience suggests that Medicontur Bi-Flex ELON can be used in presbyopia correction in patients with mild ocular pathologies or previous ocular surgeries.
Non-diffractive Extended Depth of Focus (EDoF) IOLs. The latest generation of presbyopia-correcting IOLs.
Using several physical or optical principles, ELON IOL aims to satisfy the visual needs of patients who lead an active lifestyle, while minimising the risk of dysphotopsia compared to diffractive technologies.
Outstanding distance and intermediate vision with functional near vision
- Distance vision -0.04 + 0.08 logMAR for an active lifestyle
- Intermediate vision 0.08 + 0.18 logMAR with a wide defocus range
- Near vision 0.19 + 0.26 logMAR for reading and handcrafts, often without glasses
EDoF Toric 877PETY preloaded injector system. Single piece, sterile, foldable aspheric hydrophobic acrylic IOL with UV blocker and blue light filter.
Download
Technical specifications
Brochures & Manuals
Description & Technical Specs
Medicontur Bi-Flex ELON Toric
877PETY
Single piece, sterile, foldable aspheric hydrophobic acrylic intraocular lens (IOL) with UV blocker and blue light filter. The optic is EDOF. The IOL is available as part of a preloaded injector system.
Power range
Standard: +10.0 D → +30.0 D (0.5 D steps)
Cylinders: | T2: 1.0 D | T3: 1.5 D | T4: 2.25 D | T5: 3.0 D |
T6: 3.75 D | T7: 4.5 D | T8: 5.25 D* | T9: 6.0 D* | |
*available above +11.0 D SEQ |
Hydrophobic acrylic with UV blocker and blue light filter
Refractive Index: 1.47
Abbe Number: 58
Design
Optic Diameter: 6mm
Overall Diameter: 13mm
Optic Design: Aspheric – Aberration Neutral Biconvex (+10.0 D → +30.0 D)
Nominal A-constant: 118.9
Contact Angle: 124° contact angle with the capsular bag (measured in a 10 mm standard capsular bag simulator)
EDOF Zone: Refraction-based central Wavefront Linking zones
Haptic Design: Posterior vaulting fenestrated C-loops with 0° angulation
PCO Prevention: 360° sharp edge
Shelf Life: 2.5 years after sterilisation
Injection
Estimated Incision Size: 2.2mm
Compatible injector: POB-MA single use | Pre-loaded injector
Constants
SRK/T A-Constant: A = 118.9
Haigis: a0 = 1.32 | a1 = 0.4 | a2 = 0.1
Hoffer Q: pACD = 5.46
Holladay I: SF = 1.7
Barrett Universal II: LF = 1.83
Holladay II: ACD = 5.49 | SF = 1.73