HOYA Vivinex Gemetric Plus Toric XY1-GPT
The preloaded trifocal IOL designed to provide a full range of vision in all light conditions.
Preloaded trifocal IOL
Excellent vision at all distances
Performs in all light conditions
HOYA Vivinex Gemetric Plus Toric XY1-GPT
HOYA Vivinex™ Gemetric™ Plus Toric IOL is indicated for visual correction of aphakia and pre-existing corneal astigmatism. A glistening-free hydrophobic trifocal IOL with proprietary aspheric optic, it is designed to provide excellent near vision, while maintaining good distance and intermediate vision.
"The balance between the Vivinex™ Gemetric™ and the Vivinex™ Gemetric™ Plus gives a very smooth transition from far to intermediate to near vision."
Erik L. Mertens, MD, FEBO, FWCRS, PCEO, Medical Director, Medipolis-Antwerp Private Clinic, Antwerp, Belgium"I think HOYA Surgical Optics has got it right and is a notch above other companies. With full range of vision IOLs available in two designs, the Vivinex™ Gemetric™ and Vivinex™ Gemetric™ Plus, have different light distributions weighted to either distance or near vision."
Dylan A. Joseph, MBChB, Dip(Ophth), FC Ophth, MMEd, Vision for Life Clinic, South AfricaBuilt on the Vivinex™ Platform
- Glistening-free hydrophobic acrylic IOL material
- Proprietary aspheric optic design for improved image quality
- Active oxygen processing treatment, a smooth surface and square optic edge to reduce PCO
- Textured-rough haptic surface for better grip inside the capsular bag and designed to reduce the potential for adhesion to the optic surface
- Reliable outcomes through outstanding rotational stability
Features
- Textured-rough haptic surface
- 3.2 mm diffractive zone (on anterior surface)
- Thin & textured optic edge
- Axis orientation marks (on posterior surface)
- Aspheric design
- Square posterior optic edge
Download
Technical specifications
Brochures & Manuals
Description & Technical Specs
HOYA Vivinex™ Gemetric™ Plus Toric XY1-GPT
Optic design |
Biconvex with thin textured optic edge Anterior: Aspheric diffractive/refractive design |
|||||||||||||||||||||||||||||
Optic & haptic materials |
Hydrophobic acrylic Vivinex™ with UV- and blue light filter | |||||||||||||||||||||||||||||
Haptic design |
Textured-rough haptic surface | |||||||||||||||||||||||||||||
Diameter (optic/OAL) |
6.00 mm / 13.00 mm | |||||||||||||||||||||||||||||
IOL Power (spherical equivalent) |
+10.00 D to +30.00 D in increments of 0.50 D | |||||||||||||||||||||||||||||
Add power at IOL plane |
Intermediate: +1.75 D Near: +3.50 D |
|||||||||||||||||||||||||||||
Nominal A-constant** |
119.0 | |||||||||||||||||||||||||||||
Injector |
multiSert™ preloaded | |||||||||||||||||||||||||||||
Front injector tip outer diameter |
1.70 mm | |||||||||||||||||||||||||||||
Recommended incision size |
2.20 mm | |||||||||||||||||||||||||||||
Cylinder power at IOL plane |
1.00 D 1.50 D to 3.75 D in 0.75 D increments |